SONATEC - Sound & Concentration
SONATEC is a high-precision sensor for continuous concentration measurement in two-component mixtures . It is based on measuring the speed of sound in the liquid. Designed for applications requiring maximum sensitivity and very high accuracy – with simple operation and maintenance-free performance .
Application
SONATEC is suitable for measuring concentrations in various media. Typical applications include:
- Concentration determination in the process
- Phase detection
- Process monitoring (e.g., in case of changing mixing ratios)
Measurement principle (speed of sound)
- A piezoelectric element generates a sound pulse in an ultrasonic transmitter .
- The pulse travels perpendicular to the product flow towards an ultrasound receiver and is detected there.
- The distance between the transmitter and receiver is known.
- The speed of sound is determined from the measured transit time .
From the speed of sound to concentration
- Every liquid has a specific speed of sound .
- The relationship between concentration and speed of sound can be described in a product-specific way using a mathematical polynomial .
- Centec uses polynomials for a large number of products .
Temperature compensation
- Temperature drifts are automatically compensated via an internal Pt1000 sensor .
Your advantages at a glance
- Very high accuracy for determining concentrations in 2-component mixtures
- Patented, compact design ; local display available (depending on version)
- Wide selection of materials and connection options
- Hygienic design and full CIP capability
- Maintenance-free and easy to use
- European patent application: 1 439 438 B1
Technical data
Measuring range: 0 - 3,000 m/s
Accuracy: ± 0.1 m/s
Reproducibility: ± 0.01 m/s
Response time: ≤ 1 s
Operating pressure: max. 50 bar
Operating temperature: -25 to +125 °C
Temperature sensor: Pt1000
Material: 1.4404/1.4435/AISI 316L; Hastelloy; tantalum; others on request
Connections: compatible with Varivent© inline housings DN40 - DN150; others available on request
Input (transmitter version): 6 x digital (24 VDC)
Output (transmitter version): 3 x digital (24 VDC) & 2 x analog (4 - 20 mA)
Profibus DP (Transmitter Version): Option
Profibus DP (sensor without local display): Standard
Protection rating: IP65
Explosion protection (ATEX): Ex II 2G EEx d IIC T6 (option)
Power supply: 24 VDC
contact
For selection, interpretation and appropriate integration into your process, please use the contact form below.
Modular design & extensions
RHOTEC – Density & Concentration
COMBITEC – Concentration analysis (3-component)
EXTRACT MONITOR – Inline extract measurement (°Plato)
PLATO MONITOR – Inline °Plato measurement
OECHSLE MONITOR – Inline Oechsle measurement
Sensors & Measurement Technology