PLATO MONITOR
Original Gravity Measurement by Sound Velocity
The PLATO MONITOR is a variant of SONATEC for measuring the original gravity of beer during brewing. It is used for brand identification, phase separation and blending during beer filtration and before filling.
Measuring Principle
For sound velocity measurement, an ultrasonic transmitter generates a sound pulse that is detected by an ultrasonic receiver. The measured transit time is evaluated in °Plato using a product-specific polynomial.
Applications
Beer
Brewing Process
Brand Identification
Phase Separation
Blending
Beer Filtration
Filling
Temperature drift of the measurement signal is automatically compensated. European patent application: 1 439 438 B1.
Technical Data
Measuring Principle: Sound Velocity Measurement / SONATEC
Measuring Range: 0 - 25 °Plato
Accuracy: ± 0,05 °Plato
Product Temperature During Measurement: -3 to +25 °C
Response Time: ≤ 1 s
Operating Pressure: max. 16 bar
Operating Temperature / Temperature Sensor: -25 to +125 °C / Pt1000
Material: 1.4404 / 1.4435 / AISI 316L; Hastelloy; tantalum; others on request
Input: 1 x analog (4 - 20 mA) & 6 x digital (24 VDC)
Output / Fieldbus: 2 x analog (4 - 20 mA) & 3 x digital (24 VDC) optional: PROFIBUS DP & PROFINET
Enclosure Rating: IP65
Power Supply: 24 VDC
Highly Accurate Original Gravity Measurement: Determination during the brewing process.
Brand Identification and Phase Separation: Use during filtration and blending.
Hygienic Design: Various materials and flange connections.
Modular Design & Extensions
RHOTEC – Density & Concentration
SONATEC – Ultrasonic Measurement & Concentration