top of page
CARBOTEC NIR – CO₂ (Optical)

CARBOTEC NIR – CO₂ (Optical)

Optical CO₂ Measurement in Liquids

CARBOTEC NIR measures dissolved carbon dioxide in carbonated beverages such as beer, sparkling wine and soft drinks. Optical ATR/NIR measurement determines the CO₂ content directly in the running process.

Measuring Principle

Near-infrared light passes through a sapphire crystal and is reflected several times at its inner surfaces. CO₂ molecules absorb a specific wavelength. The reduced light intensity is used to determine the CO₂ content.

Applications

  • Beer

  • Sparkling Wine

  • Soft Drinks

  • Dissolved CO₂

  • Carbonated Beverages

  • In-line Measurement

Temperature drift of the measurement signal is automatically compensated.

Technical Data

Measuring Principle: Optical ATR/NIR Measurement

Measuring Range: 0 - 10 g/l

Accuracy: ± 0,1 g/l

Repeatability: ± 0,02 g/l

Response Time: ≤ 3 s

Operating Pressure: max. 10 bar

Operating Temperature / Temperature Sensor: -10 to +85 °C / Pt100

Material: 1.4404 / AISI 316L, sapphire glass, EPDM (FDA), PTFE (FDA)

Input: 1 x analog (4 - 20 mA) & 6 x digital (24 VDC)

Output / Fieldbus: 2 x analog (4 - 20 mA) & 3 x digital (24 VDC) optional: PROFIBUS DP & PROFINET

Enclosure Rating / Supply: IP65 / 24 VDC

Optical ATR Technology: Measurement principle using near-infrared light.

Robust Evaluation: Unaffected by other gases, colour, turbidity and viscosity.

Virtually Maintenance-Free: No moving parts in the sensor head.

Modular Design & Extensions

CARBOTEC TR-PT – CO₂ (Pressure-Temperature)

Carbonator – Carbonation

DeCarbonator – Decarbonation & Carbonation

CarboBlender – High Gravity Blending & Carbonation

Sensors & Measurement Technology

Processes that inspire. Technology that thinks ahead.

Learn more about our systems and services. Contact us for project-specific proposals and technical consultation.

Wilhelm-Roentgen-Straße 10, D-63477 Maintal