top of page
HYDROTEC TC

HYDROTEC TC

HYDROTEC TC is a thermal-conductivity sensor for continuous measurement of dissolved and gaseous hydrogen (H₂). It is designed for in-line measurements from trace concentrations to saturation and is particularly suitable for applications in water-steam cycles and power generation.

Applications

  • Power & Steam / Water-Steam Cycle
  • Dissolved and gaseous process streams
  • Continuous in-line monitoring of H₂

Measuring Principle

H₂ diffuses through a gas-permeable membrane into the measuring chamber. The change in thermal conductivity of the gas mixture is detected, and the dissolved concentration is derived from the H₂ partial pressure. Temperature is automatically compensated.

Technical Data

  • Dissolved H₂: 0–2 ppm
  • H₂ partial pressure: 0–1,5 bar
  • Cycle time: 15 s
  • Response Time: approx. 30 s
  • Accuracy: ±1 % of reading*
  • Temperature Compensation: 0 to +45 °C
  • CIP/SIP: up to 120 °C
  • Process pressure: 0–20 bar
  • Wetted materials: 316L stainless steel, PFA
  • Enclosure Rating: IP65
  • Weight: 0,6 kg
  • Sensor cable: 3–100 m

Extension

Optionally with CENTEC TC ANALYZER as the evaluation unit for display, alarm functions and signal integration.

* 1 % of the reading or the minimum value, whichever is greater.

  • Evaluation unit / Analyzer

    HYDROTEC TC is optionally available with the CENTEC TC ANALYZER as the evaluation unit. The analyzer displays concentration and temperature and provides alarm and signal integration into the process control system.
  • Downloads (PDF, English)

Processes that inspire. Technology that thinks ahead.

Learn more about our systems and services. Contact us for project-specific proposals and technical consultation.

Centec RRR Systems And Sensors PVT. LTD., RRR Center, W-14, TTC Pawane MIDC, Navi Mumbai - 400 705, Maharashtra, INDIA.

bottom of page