top of page
OXYTRANS ATEX

OXYTRANS ATEX

Measure O₂ in Liquids and Gases

OXYTRANS ATEX measures O₂ in deaerated water, wort, beer, beverages, liquid food products, CO₂ and inert gases. This version is documented for applications requiring maximum sensitivity and high accuracy.

Measuring Principle

Indicator molecules in the optical window are excited by blue-green LED light. Oxygen transfers energy from the excited molecules and reduces the detected signal. Other gases do not affect the measurement result.

Applications

  • Deaerated Water
  • Wort
  • Beer
  • Beverages
  • Liquid Food Products
  • CO₂
  • Inert Gases
  • ATEX Option

Optical technology requiring no replacement of electrolyte or membrane; hygienic design with various flange connections.

Technical Data

Measuring Ranges, Liquid Phase: I) 1 ppb - 2 ppm
II) 30 ppb - 35 ppm

Accuracies, Liquid Phase: I) ± 1 ppb
II) ± 30 ppb

Measuring Ranges, Gas Phase: I) 0 - 4,2 % O₂
II) 0 - 50 % O₂

Accuracies, Gas Phase: I) ± 0,002 % O₂
II) ± 0,03 % O₂

Response Time / Operating Pressure: t90 ≤ 10 s / max. 12 bar

Operating Temperature: -5 to +55 °C (Pt100); optional +98 °C

Material: 1.4404 / AISI 316L, silicone (FDA), PTFE (FDA)

Input: 1 x analog (4 - 20 mA) & 3 x digital (24 VDC)

Output / Fieldbus: 2 x analog (4 - 20 mA) & 3 x digital (24 VDC)
optional: PROFIBUS DP & PROFINET

Enclosure Rating: IP65; optional: ATEX (II 3G Ex ic IIC T6 Gc)

Power Supply: 24 VDC

Optical Technology: No replacement of electrolyte or membrane.

Short Response Time: t90 ≤ 10 s and high long-term stability.

Hygienic Design: Various flange connections available.

Processes that inspire. Technology that thinks ahead.

Learn more about our systems and services. Contact us for project-specific proposals and technical consultation.

Wilhelm-Roentgen-Straße 10, D-63477 Maintal

bottom of page