top of page
CONCENTRATION MONITOR

CONCENTRATION MONITOR

Concentration Measurement for Documented Liquids and Mixtures

The CONCENTRATION MONITOR determines concentrations in liquid 2-component mixtures. Depending on the medium, measurement is based on density using RHOTEC or sound velocity using SONATEC; conversion uses a suitable product-specific polynomial.

Measuring Principle

RHOTEC measures density; SONATEC measures sound velocity. This physical measured variable is only output as a concentration when a suitable mathematical polynomial describes the product-specific relationship. The measurement principle and characteristic curve are selected to suit the medium and measuring range.

Applications

  • Extract / °Plato, Brix, Oechsle
  • Ethanol and Methanol
  • Sodium and Potassium Hydroxide
  • Sulphuric Acid, Phosphoric Acid, Hydrochloric Acid
  • Nitric and Boric Acid
  • Sodium Chlorite, Formalin / Formaldehyde
  • Hydrogen Peroxide, Glycerine and Glycol
  • Acetone, Ammonia, Ammonium Nitrate, Urea

Temperature drift of the measurement signal is automatically compensated. European patent application: 1 439 438 B1.

Technical Data

Density: 0,0001 - 3,0000 g/cm³

Sound Velocity: 400 - 3.000 m/s

Extract / °Plato: 0 - 30 °Plato / Extract

Brix: 0 - 80 °Brix

Oechsle: 0 - 30 °Oechsle

Accuracy, Density / Sound Velocity: ± 0,0001 g/cm³ (R) / ± 0,05 m/s (S)

Accuracy, Extract / °Plato: ± 0,03 (R) / ± 0,07 (S)

Brix Accuracy: ± 0,03 °Brix (R) / ± 0,07 °Brix (S)

Concentration Accuracy: ± 0,1 wt-%

Specific media and ranges: Ethanol and methanol 0 - 100 %; sodium and potassium hydroxide 0 - 100 %; sulphuric acid 0 - 98 %; phosphoric acid 0 - 75 %; hydrochloric acid 0 - 42 %; nitric and boric acid 0 - 63 %; sodium chlorite 0 - 30 %; formalin / formaldehyde 0 - 40 %; hydrogen peroxide 0 - 90 %; glycerine and glycol 0 - 100 %; acetone 0 - 100 %; ammonia / ammonium nitrate 0 - 100 %; urea 0 - 32 %

Two Measurement Principles: Choice of density or sound velocity.

Product-Specific Evaluation: Concentration determined using a mathematical product polynomial.

Hygienic Design: Various materials and flange connections.

Processes that inspire. Technology that thinks ahead.

Learn more about our systems and services. Contact us for project-specific proposals and technical consultation.

Wilhelm-Roentgen-Straße 10, D-63477 Maintal